Series
Showing 37–45 of 45 results
-
Design
Strength Design of Masonry #4 – Strength Design of Walls for In-Plane Loads & Seismic Detailing
$75.00 Add to cartStrength Design of Masonry #4 – Strength Design of Walls for In-Plane Loads & Seismic Detailing
This session will review strength design of shear walls, along with both seismic detailing requirements and minimum/maximum detailing requirements for such walls.
Get all 6 Strength Design of Masonry lessons at a discounted rate when buying the Strength Design of Masonry bundle. Save $30 compared to buying them separately.
$75.00 -
Design
Strength Design of Masonry #5 – Strength Design of Columns and Pilasters & System Behavior
$75.00 Add to cartStrength Design of Masonry #5 – Strength Design of Columns and Pilasters & System Behavior
Masonry columns and pilasters are often used in masonry buildings to carry large, concentrated loads, and, for pilasters, to support walls subjected to out-of-plane loads. Required detailing of these elements will be reviewed and strength design provisions will be introduced for these elements. This session of also looks at several sample masonry buildings to discuss system behavior and overall design methodology for masonry structures.
Get all 6 Strength Design of Masonry lessons at a discounted rate when buying the Strength Design of Masonry bundle. Save $30 compared to buying them separately.
$75.00 -
Anchoring
Strength Design of Masonry #6 – Strength Design Requirements for Reinforcement & Connectors
$75.00 Add to cartStrength Design of Masonry #6 – Strength Design Requirements for Reinforcement & Connectors
Reinforcement and connectors are essential to ensure a proper load path in masonry buildings. This session will review basic detailing requirements for reinforcement and connectors, and specific requirements for strength design of masonry. Lap length requirements for reinforcement, and design of anchor bolts will be reviewed.
Get all 6 Strength Design of Masonry lessons at a discounted rate when buying the Strength Design of Masonry bundle. Save $30 compared to buying them separately.
$75.00 -
TMS 402/602-22 Review – All Lessons
During this five-part Night School webinar series, masonry experts and Committee leaders will review the new standards TMS 402-22 Building Code Requirements for Masonry Structures and TMS 602 Specification for Masonry Structures and changes made since the 2016 edition. These standards will form the basis for masonry design provisions in the 2024 International Building Code and other model building codes and include some major new provisions that include a new appendix on masonry partition walls reinforced with Glass Fiber Reinforced Polymer (GFRP) reinforcement, completely revised anchored and adhered veneer provisions, and enhancements throughout the standards. Read more about each session at the links below. Attendees are also encouraged to have a copy of the new TMS 402/602-22.
Session 1 – Overview of Changes in TMS 402/602-22 and Review of the Specification for Masonry Structures, Presented by John Chrysler, PE, FTMS
Session 2 – Major Structural Design Changes in TMS 402/602-22, Presented by Richard Bennett, PhD, PE, FTMS, University of Tennessee, Knoxville
Session 3 – Seismic/Limit States Design per TMS 402/602-22, Presented by John Hochwalt, PE, SE, FTMS, KPFF Consulting Engineers
Session 4 – Masonry Veneer Requirement Changes in TMS 402/602-22, A Whole New Chapter, Presented by Brian Trimble, PE, CDT, LEED AP, FASTM, IMI
Session 5 – Using the New Appendix D on Composite Reinforcement in Masonry, Presented by Heather Sustersic, P.E., Colby Company Engineering
This product provides access to all 5 TMS 402/602-22 Review lessons.
$360.00 -
Codes & Standards
TMS 402/602-22 Review #1: Overview of Changes in TMS 402/602-22 and Review of the Specification for Masonry Structures
$80.00 Add to cartTMS 402/602-22 Review #1: Overview of Changes in TMS 402/602-22 and Review of the Specification for Masonry Structures
This course reviews the major changes from the 2016 edition to the 2022 edition of TMS 402/602. The 2022 edition was created using the first six-year revision cycle, allowing more comprehensive consideration of significant changes and reorganization of these Masonry Standards. In addition to reviewing the changes to the standards, this presentation reviews the Specification for Masonry Structures (TMS 602) and discusses the importance of why designers should be aware of how masonry is constructed.
Learning Objectives:
- Evaluate and utilize Masonry Standard updates
- Specify documents that are consistent with the current code
- Organize construction documents to be consistent with current codes and standards
- Recognize issues related to masonry construction
View other courses in this series or purchase the TMS 402/602-22 Review Bundle to access all 6 and save 10% compared to buying them separately.
$80.00 -
Codes & Standards
TMS 402/602-22 Review #2: Major Structural Design Changes in TMS 402/602-22
$80.00 Add to cartTMS 402/602-22 Review #2: Major Structural Design Changes in TMS 402/602-22
This webinar will provide an overview of the major structural changes in TMS 402-22. One of the biggest changes was the introduction of compression-controlled sections in strength design. As a result of this, the maximum reinforcement provisions were deleted except for beams and intermediate and special shear walls under in-plane loads. The basis for the provisions, the impact on design, and some design aids will be presented.
Other structural changes that will be covered include: definition of net shear area particularly for beams, anchor bolt steel strength changing from being based on yield strength to ultimate strength, an increase of the allowable compressive force for masonry in allowable stress design, a change in the partially grouted shear wall factor, and an increase in the allowable shear friction strength as well as a change in the nominal shear friction strength for shear span ratios greater than 1. The potential impacts of these changes will also be reviewed.
Learning Objectives:
- Use the compression-controlled strength design provisions in TMS 402-22 and compare designs to TMS 402-16.
- Evaluate the change in anchor bolt steel strength in TMS 402-22
- Solve for shear friction strength for shear span ratios greater than 1 in TMS 402-22
- Name at least three other structural changes in TMS 402-22 and explain how they affect design
View other courses in this series or purchase the TMS 402/602-22 Review Bundle to access all 6 and save 10% compared to buying them separately.
$80.00 -
Codes & Standards
TMS 402/602-22 Review #3: Seismic/Limit States Design per TMS 402/602-22
$80.00 Add to cartTMS 402/602-22 Review #3: Seismic/Limit States Design per TMS 402/602-22
This session of the TMS 402/602-22 Night School will review the changes to the provisions in Chapter 7 and Appendix C that effect the seismic design of masonry structures. This will include revisions to the requirements for special reinforced masonry shear walls, changes to the requirements based on the assigned Seismic Design Category, and changes made to the treatment of seismic displacements in the masonry code, including a new deformation compatibility provision. The potential impacts of these changes will also be reviewed.
Learning Objectives:
- Review the changes made in TMS 402/602-22 that affect seismic design
- Understand the technical background for the revisions to the provisions for special reinforced masonry shear walls
- Review the relationship between ASCE 7-22 seismic displacements and the TMS 402 provisions including the use of MCER displacements
- Understand the new deformation compatibility provision and its application.
View other courses in this series or purchase the TMS 402/602-22 Review Bundle to access all 6 and save 10% compared to buying them separately.
$80.00 -
Codes & Standards
TMS 402/602-22 Review #4: Masonry Veneer Requirement Changes in TMS 402/602-22, A Whole New Chapter
$80.00 Add to cartTMS 402/602-22 Review #4: Masonry Veneer Requirement Changes in TMS 402/602-22, A Whole New Chapter
The chapter on masonry veneer has been extensively revised and updated for the 2022 edition of TMS 402/602. Prescriptive requirements for both anchored and adhered veneer have been simplified with many of the major requirements now found in a one or two tables. A tributary area method was added for engineered design of anchored veneer as well as guidance for modeling anchored veneer in a full engineered design. Both the prescriptive and engineered provisions for adhered veneer were enhanced. Learn how to design masonry veneer with the new provisions and determine where your specifications need to be upgraded to meet the new requirements. Also learn about updated installation and inspection requirements and allowable tolerances for both types of veneer in construction. The updated requirements will simplify the design of your masonry veneer projects and assure the most efficient design methods are being used.
Learning Objectives:
- Learn about the updated prescriptive requirements for anchored veneer including appropriate wind loading and deflection of backing requirements as well as requirements for veneer ties and their spacing.
- Review new rational design methods for anchored veneer using the Engineered Design Methods: Tributary Area Method and Engineering Analysis Method.
- Learn about the updated prescriptive requirements for adhered veneer including unit limitations, mortar material requirements and required system components.
- Discuss needed updates to project specifications
View other courses in this series or purchase the TMS 402/602-22 Review Bundle to access all 6 and save 10% compared to buying them separately.
$80.00 -
Codes & Standards
TMS 402/602-22 Review #5: Using the New Appendix D on Composite Reinforcement in Masonry
$80.00 Add to cartTMS 402/602-22 Review #5: Using the New Appendix D on Composite Reinforcement in Masonry
Glass Fiber Reinforced Polymer (GFRP) reinforcement in concrete was first introduced over 25 years ago by way of ACI 440R, but prior to TMS 402/602 2022, no companion guidelines existed for masonry construction. The new Appendix D of TMS 402/602 is a first standard in the U.S. for the use of GFRP reinforcement in masonry. GFRP reinforcement has applications in masonry for specialty use near electromagnetic equipment and in locations exposed to severe environments. Learn how to use the new Appendix D to design and specify GFRP reinforced masonry for your next project.
View other courses in this series or purchase the TMS 402/602-22 Review Bundle to access all 6 and save 10% compared to buying them separately.
$80.00